Since only 417 Masters of Wine exist globally (and their palates and noses)—and they are amazing in identifying wines by grape varietal or blend, type, vintage and location—it is a good idea to have some automated backup when it comes to wine fraud detection. Aside from other analytical methods, nuclear magnetic resonance (NMR) spectroscopy can be used in the authentication of wine. The new proton measurement 1H NMR Method with easier sample preparation is recommended for the investigation of wine fraud, to detect for example the addition of water or sugar. NMR spectroscopy measures several compounds of a wine at once and therefore is able to detect a fingerprint of a wine, such as the geographic origin or grape varietal.
Robust, reproducible quantitation of pesticide residues in food is the most important step in ensuring food safety, and hence, forms one of the most important responsibilities of every food safety laboratories. The analytical process involves characterization and identification followed by quantitation of pesticides across different food matrices. Considering the growing list of pesticides and their adverse effects even for very low concentrations, quantitation with confidence for every sample can pose some significant challenges to the analytical scientist.
Typical practices of using pesticides to control pests and improve yields can often pose a serious risk to human health if and when used inappropriately. Improper use of pesticides in breach of approved procedures, or those that are applied to crops for which their use has not been authorized, unacceptable amounts of these potentially dangerous compounds can find their way onto the plates of consumers.
In order to ensure food is safe for consumption, laboratories require robust, reliable and cost-effective workflows, incorporating highly effective sample preparation steps, separation methods and detection techniques. Owing to its selectivity, specificity, sensitivity, robustness and universal approach, liquid chromatography coupled to triple quadrupole mass spectrometers (LC-MS/MS) are widely used for quantitation of pesticides in food.
Food standards are growing increasingly stringent, so leading laboratories must ensure they consistently meet the requirements of regulators. Thankfully, the latest comprehensive pesticide workflow solutions are helping laboratories deliver the very highest quality of pesticide quantitation, on time and on budget.
Optimizing Sample Preparation
Regardless of the food product that is being tested, pesticide residue workflows typically start with sample preparation, following homogenization and residue extraction steps. This stage is one of the most important parts of the workflow, however, very often they are not highlighted.
The heterogeneity of the sample matrix, as well as the wide variety of pesticide compounds that must be extracted, can significantly add to the complexity of this task. For example, pesticide residues can be lost during sample grinding, compromising the accuracy of quantitative analysis. Loss of critical pesticides can also occur through hydrolysis by water or enzymatic degradation as enzymes are released from cells, or by the formation of insoluble complexes due to interaction of the analyte with matrix components. Each of these factors can impact the quantitation of pesticide residues in food.
Homogenization is followed by solvent extraction and cleanup. Extraction could traditionally be a time-consuming process, often requiring relatively large amounts of sample, and involving use of multiple solvents and work-up steps. In addition, results from this step can vary based on matrix type and pesticides that are being monitored. Time-consuming sample cleanup steps, based on separation techniques such as gel permeation chromatography, could also be necessary, thereby adding another layer of complexity.
The widespread adoption of sample preparation strategies based on QuEChERS (Quick, Easy, Cheap, Effective, Rugged and Safe) methods has significantly simplified the process of residue extraction for a wide range of food types, especially for high-moisture content samples. These generic extraction approaches, coupled with “quick and easy” cleanup techniques such as dispersive solid phase extraction, are able to comprehensively extract residues with a range of different chemical properties, resulting in more consistent and reliable quantitation.
The universal and easy-to-implement nature of QuEChERS methods has also allowed laboratories to reduce the complexity of their workflows. Their simplicity is such that many suppliers are now offering all-in-one kits containing all of the necessary pre-weighted reagents and supplies, which laboratories can use straight from the box. And as they require very little sample material, solvent or equipment, and eliminate the need for time-intensive homogenization steps, they are also helping to reduce laboratory waste and cut operational costs.
The Need for LC-MS/MS Technology
Once analytes are extracted from the matrix, food safety laboratories require reliable, sensitive and precise separation, detection and quantitation technologies to determine their concentration.
As indicated above, LC-MS/MS technology with triple quadrupole mass spectrometers are often the go-to choice for quantitation applications. The high selectivity and sensitivity of these instruments allow analysts to confidently identify pesticides against target lists and accurately quantify even trace levels. Figure 1 shows the distinct separation obtained for a leek sample spiked with more than 250 pesticides at a concentration of 100 µg/kg. The mass range, robustness, specificity, selectivity of the triple quadrupole instrument ensures the ability to handle a wide variety of sample types and deliver reliable results in a cost-effective manner.
Conclusion
To ensure the food on our plates does not contain potentially harmful levels of pesticides, laboratories require robust workflows for their analysis and targeted quantitation. Improvements in the sample preparation methods that are used to extract pesticide residues from food samples, as well as in the sensitivity, accuracy, robustness and reliability of the triple quadrupole instruments used for analyte detection, are helping food safety laboratories confidently quantify these compounds even in trace amounts.
Acknowledgements
This article is based on research by Katerina Bousova, Michal Godula, Claudia Martins, Charles Yang, Ed Georg, Neloni Wijeratne & Richard J. Fussell, Thermo Fisher Scientific, Dreieich, Germany, Thermo Fisher Scientific, California, USA, Thermo Fisher Scientific, Hemel Hempstead, UK.
In ongoing efforts to eliminate foodborne illness, the FDA recently issued the next step in rules designed for the enforcement of FSMA. The rules are aimed at modernizing food manufacturing processes after a wave of deadly outbreaks in the past decade stemming from contaminated cantaloupes, apples, spinach, lettuce, peanut butter, ice cream, cucumbers and other products. The rules require companies to draw up and implement written plans for keeping food safe. An important part of any food safety plan is the implementation of methods to verify that the controls put in place are working.
The food industry faces many challenges in meeting these new regulations. Two significant technical challenges for control verification are that the testing process takes too long and the sampling plans are often inadequate.
The pathogen testing process for all commercially available diagnostic tests requires an upfront culture or growth step to allow any pathogens present to multiply to a level that they can be detected by the test in use. This growth step, referred to by microbiologists as enrichment, is especially challenging in heavily processed foods and environmental samples, because the bacteria present in the sample have been stressed and are not in a rapid growth phase at the time of sampling. Advances in diagnostic sensitivity and robustness have reduced the amount of time required for enrichment from three or more days with traditional methods to about 24 hours on average with rapid methods. Even with rapidly growing and low-stress organisms such as E. coli O157:H7, enrichments take more than eight hours before implementing the diagnostic. The time required for this growth step creates a bottleneck in the production and distribution process. Although diagnostic companies are continuously improving the sensitivity of their methods and new methods are constantly being developed, there are practical limitations that have thus far prevented the elimination of the upfront culture step prior to testing. Historically, improvements in the sensitivity of rapid food pathogen diagnostics have been traded for time. In other words, having a more sensitive test means that fewer bacteria are needed for detection and therefore, less time is needed for bacteria to divide during the enrichment step. Some commercially available assays require as few as 1,000 to 10,000 target cells in the sample for detection. Since the purpose of the enrichment step is to increase the number of target pathogens in the sample to a detectable limit and bacteria reproduce by cell division, further diagnostic sensitivity improvements would need to be greater than ten-fold to have a significant impact on further reducing enrichment times.
Unreliable sampling methods are an even bigger issue for industry. An example demonstrating current practice is a field of 40,000 heads of lettuce with four (.01% of the total) heads of lettuce contaminated by a pathogen. The current best practice is to go into the field and collect 60 (.15% of the total) leaves from the heads of lettuce, mash them together and test them for contamination. The probability of this sampling method finding the four contaminated heads of lettuce in the sample is much less than 1%. When the undiscovered four heads of lettuce are washed with the other 39,996 heads of lettuce, cross contamination occurs and people get sick.
Technology advances that reduce or eliminate the requirement for enrichment and make the sampling process more reliable could have a big impact on improving control verification testing. But, those advances need to be delivered in a practical and affordable manner. I recently learned about a technology that has great potential to make improvements on both of these fronts, especially for the produce industry and any process that is able to use a wash step as a control point. The recently patented OmniFresh sampling system (developed by OmniFresh, LLC) concentrates a sample from the food processing wash water, allowing immediate testing representative of the food being processed. The concentration process is performed during the entire washing cycle for a lot and is consequently representative of the entire lot.
Concentration technology has been used for many years by academic researchers and scientists to collect samples for biological testing. Ultrafiltration methods for concentrating samples have typically used smaller sample sizes in the 1-10 liter range. The OmniFresh system allows for very large samples to be concentrated, typical volumes of 400 liters are concentrated to 50 ml.
The concentration process takes about one hour to complete after the first wash cycle. During processing, a side stream of water from the first wash tank is diverted to the concentrator unit. Tens to hundreds of gallons of wash water, depending on the size of the wash tank and the type and amount of produce being washed, flows into the concentrator. Throughout the sample collection period, large particulates are removed through a course filtration. Using ultra-filtration, bacteria and other small particles are isolated from the large volume of wash water into a much smaller, concentrated final sample. This concentrated sample can then be tested directly by a diagnostic test, eliminating the need for enrichment.1
The wash water in the tank comes into contact with all of the produce being washed, the majority of bacteria is removed from the produce, and it then enters the wash water.2-4 This process, combined with the continuous sampling of wash water, means that low levels of intermittent contamination can be detected without testing high numbers of samples. Field testing of the OmniFresh System has returned promising results. The ability to rapidly screen produce for contamination could also provide a practical lot definition instead of cumbersome field-based definitions that can impact multiple processors.
Improvements in sample preparation and sampling technologies have much to offer the industry. Improved sampling methods which are representative of entire lots identify contaminated food earlier and with high confidence. Additionally, the negative test result is of much higher quality and will result in an increase in the overall confidence of the food supply.
The OmniFresh technology is one example of the type of improvements that are needed. More research that focuses on these most challenging aspects of control verification testing is needed.
References
Dyer, M.A. (2009). “New biosensors for food safety screening solutions.” SPIE.
Beuchat, L. R., and Ryu, J.-H. (1997). “Produce Processing Practices,” Emerg. Infect. Dis 3 (4), 459-465.
Sapers, G. M, (2001). “Efficacy of washing and sanitizing methods for disinfection of fresh fruit and vegetable products,” Food Technol. Biotechnol. 39 (4), 305-311.
U.S. Food and Drug Administration. (1998). “Water: Control of Potential Hazards: Wash Water.” Chap. II.B.2.3 in Guide to minimize microbial food safety hazards for fresh fruits and vegetables, by US FDA.
This website uses cookies so that we can provide you with the best user experience possible. Cookie information is stored in your browser and performs functions such as recognising you when you return to our website and helping our team to understand which sections of the website you find most interesting and useful.
Strictly Necessary Cookies
Strictly Necessary Cookies should be enabled at all times so that we can save your preferences for these cookie settings.
We use tracking pixels that set your arrival time at our website, this is used as part of our anti-spam and security measures. Disabling this tracking pixel would disable some of our security measures, and is therefore considered necessary for the safe operation of the website. This tracking pixel is cleared from your system when you delete files in your history.
We also use cookies to store your preferences regarding the setting of 3rd Party Cookies.
If you visit and/or use the FST Training Calendar, cookies are used to store your search terms, and keep track of which records you have seen already. Without these cookies, the Training Calendar would not work.
If you disable this cookie, we will not be able to save your preferences. This means that every time you visit this website you will need to enable or disable cookies again.
Cookie Policy
A browser cookie is a small piece of data that is stored on your device to help websites and mobile apps remember things about you. Other technologies, including Web storage and identifiers associated with your device, may be used for similar purposes. In this policy, we say “cookies” to discuss all of these technologies.
Our Privacy Policy explains how we collect and use information from and about you when you use This website and certain other Innovative Publishing Co LLC services. This policy explains more about how we use cookies and your related choices.
How We Use Cookies
Data generated from cookies and other behavioral tracking technology is not made available to any outside parties, and is only used in the aggregate to make editorial decisions for the websites. Most browsers are initially set up to accept cookies, but you can reset your browser to refuse all cookies or to indicate when a cookie is being sent by visiting this Cookies Policy page. If your cookies are disabled in the browser, neither the tracking cookie nor the preference cookie is set, and you are in effect opted-out.
In other cases, our advertisers request to use third-party tracking to verify our ad delivery, or to remarket their products and/or services to you on other websites. You may opt-out of these tracking pixels by adjusting the Do Not Track settings in your browser, or by visiting the Network Advertising Initiative Opt Out page.
You have control over whether, how, and when cookies and other tracking technologies are installed on your devices. Although each browser is different, most browsers enable their users to access and edit their cookie preferences in their browser settings. The rejection or disabling of some cookies may impact certain features of the site or to cause some of the website’s services not to function properly.
Individuals may opt-out of 3rd Party Cookies used on IPC websites by adjusting your cookie preferences through this Cookie Preferences tool, or by setting web browser settings to refuse cookies and similar tracking mechanisms. Please note that web browsers operate using different identifiers. As such, you must adjust your settings in each web browser and for each computer or device on which you would like to opt-out on. Further, if you simply delete your cookies, you will need to remove cookies from your device after every visit to the websites. You may download a browser plugin that will help you maintain your opt-out choices by visiting www.aboutads.info/pmc. You may block cookies entirely by disabling cookie use in your browser or by setting your browser to ask for your permission before setting a cookie. Blocking cookies entirely may cause some websites to work incorrectly or less effectively.
The use of online tracking mechanisms by third parties is subject to those third parties’ own privacy policies, and not this Policy. If you prefer to prevent third parties from setting and accessing cookies on your computer, you may set your browser to block all cookies. Additionally, you may remove yourself from the targeted advertising of companies within the Network Advertising Initiative by opting out here, or of companies participating in the Digital Advertising Alliance program by opting out here.